Product parameter
Types of meaning

The performance parameters
|
Model |
Parallel capacitor group capacity (kVar) |
Voltage of the capacitor (kV) |
Rated reactance rate(%) |
The rated reactive(Q) |
Rated current(A) |
Nominal capacity(kVar) |
Rated loss (W) |
|
CKSC-165/10-5 |
3300 |
11/V3 |
5 |
1.83 |
173.2 |
165 |
1650 |
|
CKSC-198/10-6 |
11/V3 |
6 |
2.2 |
173.2 |
198 |
1940 |
|
|
CKSC-396/10-12 |
12/V3 |
12 |
5.23 |
158.8 |
396 |
3200 |
|
|
CKSC-180/10-5 |
3600 |
11/V3 |
5 |
1.68 |
189 |
180 |
1800 |
|
CKSC-216/10-6 |
11/V3 |
6 |
2.02 |
189 |
216 |
2050 |
|
|
CKSC-432/10-12 |
12/V3 |
12 |
4.8 |
173.3 |
432 |
3610 |
|
|
CKSC-200/10-5 |
4000 |
11/V3 |
5 |
1.51 |
210 |
200 |
1950 |
|
CKSC-240/10-6 |
11/V3 |
6 |
1.81 |
210 |
240 |
2220 |
|
|
CKSC-480/10-12 |
12/V3 |
12 |
4.32 |
192.5 |
480 |
3750 |
|
|
CKSC-210/10-5 |
4200 |
11/V3 |
5 |
1.45 |
219.7 |
210 |
2000 |
|
CKSC-252/10-6 |
11/V3 |
6 |
1.74 |
220.5 |
252 |
2100 |
|
|
CKSC-504/10-12 |
12/V3 |
12 |
4.11 |
202.2 |
504 |
3970 |
|
|
CKSC-225/10-5 |
4500 |
11/V3 |
5 |
1.35 |
236.2 |
225 |
2130 |
|
CKSC-270/10-6 |
11/V3 |
6 |
1.61 |
236.2 |
270 |
2400 |
|
|
CKSC-540/10-12 |
12/V3 |
12 |
3.84 |
216.6 |
540 |
3950 |
|
|
CKSC-240/10-5 |
4800 |
11/V3 |
5 |
1.26 |
252 |
240 |
2150 |
|
CKSC-288/10-6 |
11/V3 |
6 |
1.51 |
252 |
288 |
2450 |
|
|
CKSC-576/10-12 |
12/V3 |
12 |
3.60 |
231 |
576 |
4300 |
|
|
CKSC-250/10-5 |
5000 |
11/V3 |
5 |
1.21 |
262 |
250 |
2090 |
|
CKSC-300/10-6 |
11/V3 |
6 |
1.45 |
262 |
300 |
2480 |
|
|
CKSC-600/10-12 |
12/V3 |
12 |
3.45 |
240.7 |
600 |
4480 |
|
|
CKSC-270/10-5 |
5400 |
11/V3 |
5 |
1.12 |
283.5 |
270 |
2410 |
|
CKSC-324/10-6 |
11/V3 |
6 |
1.34 |
283.5 |
324 |
2750 |
|
|
CKSC-648/10-12 |
12/V3 |
12 |
3.2 |
259.9 |
648 |
4760 |
|
|
CKSC-300/10-5 |
6000 |
11/V3 |
5 |
1.01 |
315 |
300 |
2480 |
|
CKSC-360/10-6 |
11/V3 |
6 |
1.21 |
315 |
360 |
2750 |
|
|
CKSC-720/10-12 |
12/V3 |
12 |
2.88 |
288.8 |
720 |
5080 |

Product detail pictures:
Related Product Guide:
Cooperation
With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and development, we are going to build a prosperous future alongside one another with your esteemed enterprise for Popular Design for Protective Current Transformers - CKSC Series Resin Insulation Dry-Type Core Series Reactor – Pengbian , The product will supply to all over the world, such as: Washington , Armenia , Sevilla , we are fully determined to control the whole supply chain so as to provide quality products at competitive price in a timely manner. We are keeping up with the advanced techniques, growing through creating more values for our clients and society.