Model meaning
| Model | S□-M xxxx/xx | |||
| S | □ | M | xxxx | xx |
| Three-phase | Performance level code | Fully sealed | Rated capacity (kVA) | Rated high voltage (kV) |
Product Standards
GB1094.1-2-2013 GB/T 6451-2015
Rated high voltage: 10 (10.5, 11, 6, 6.3, 6.6) kV
Rated low voltage: 0.4kV
Tap range: non-excitation voltage regulation (±5%, ±2×2.5%)
On-load voltage regulation: (±4×2.5%)
Connection group: Dyn11 or Yyn0
Insulation level: LI75AC35/AC5
The main technical parameters
| Type | Rated Capacit | Voltage Combination | nSymbol | No-Load Loss(kw) | Load Loss(kw) | No-Load Current(%) | Circuit Impedance | ||
| HV | Tapping | LV | |||||||
| S11-M-30/10 | 30 | 66.31010.5
11 |
(±5%)(±2*2.5%) | 0.4 | Yyn0Yzn11Dyn11 | 0.10 | 0.60 | 1.4 | 4 |
| S11-M-50/10 | 50 | 0.13 | 0.87 | 1.3 | 4 | ||||
| S11-M-63/10 | 63 | 0.15 | 1.04 | 1.2 | 4 | ||||
| S11-M-80/10 | 80 | 0.18 | 1.25 | 1.1 | 4 | ||||
| S11-M-100/10 | 100 | 0.20 | 1.50 | 1.1 | 4 | ||||
| S11-M-125/10 | 125 | 0.24 | 1.80 | 1.0 | 4 | ||||
| S11-M-160/10 | 160 | 0.28 | 2.20 | 0.9 | 4 | ||||
| S11-M-200/10 | 200 | 0.34 | 2.60 | 0.9 | 4 | ||||
| S11-M-250/10 | 250 | 0.40 | 3.05 | 0.8 | 4 | ||||
| S11-M-315/10 | 315 | 0.48 | 3.65 | 0.8 | 4 | ||||
| S11-M-400/10 | 400 | 0.57 | 4.30 | 0.8 | 4 | ||||
| S11-M-500/10 | 500 | 0.68 | 5.15 | 0.7 | 4 | ||||
| S11-M-630/10 | 630 | 0.81 | 6.20 | 0.7 | 4.5 | ||||
| S11-M-800/10 | 800 | 0.98 | 7.50 | 0.6 | 4.5 | ||||
| S11-M-1000/10 | 1000 | 1.15 | 10.30 | 0.6 | 4.5 | ||||
| S11-M-1250/10 | 1250 | 1.36 | 12.00 | 0.5 | 4.5 | ||||
| S11-M-1600/10 | 1600 | 1.64 | 14.50 | 0.5 | 4.5 | ||||
| S11-M-2000/10 | 2000 | 2.24 | 18.50 | 0.5 | 4.5 | ||||
| S11-M-2500/10 | 2500 | 2.65 | 23.00 | 0.4 | 5 | ||||
| Type | Rated Capacit | Voltage Combination | nSymbol | No-Load Loss(kw) | Load Loss(kw) | No-Load Current(%) | Circuit Impedance | ||
| HV | Tapping | LV | |||||||
| S11-50/35 | 50 | 35 | (±5%)(±2*2.5%) | 0.4 | Yyn0Dyn11 | 0.17 | 1.25 | 1.4 | 6.5 |
| S11-80/35 | 80 | 0.22 | 1.65 | 1.3 | 6.5 | ||||
| S11-100/35 | 100 | 0.24 | 2.03 | 1.25 | 6.5 | ||||
| S11-125/35 | 125 | 0.27 | 2.35 | 1.2 | 6.5 | ||||
| S11-160/35 | 160 | 0.31 | 2.82 | 1.2 | 6.5 | ||||
| S11-200/35 | 200 | 0.36 | 3.30 | 1.1 | 6.5 | ||||
| S11-250/35 | 250 | 0.42 | 3.90 | 1.0 | 6.5 | ||||
| S11-315/35 | 315 | 0.49 | 4.70 | 1.0 | 6.5 | ||||
| S11-400/35 | 400 | 0.6 | 5.70 | 0.9 | 6.5 | ||||
| S11-500/35 | 500 | 0.7 | 6.90 | 0.9 | 6.5 | ||||
| S11-630/35 | 630 | 0.82 | 8.20 | 0.8 | 6.5 | ||||
| S11-800/35 | 800 | 1.0 | 10.00 | 0.7 | 6.5 | ||||
| S11-1000/35 | 1000 | 1.17 | 12.00 | 0.7 | 6.5 | ||||
| S11-1250/35 | 1250 | 1.43 | 14.00 | 0.6 | 6.5 | ||||
| S11-1600/35 | 1600 | 1.72 | 16.50 | 0.6 | 6.5 | ||||
| S11-2000/35 | 2000 | 2.14 | 18.50 | 0.5 | 6.5 | ||||
| S11-2500/35 | 2500 | 2.65 | 20.24 | 0.5 | 6.5 | ||||
Product detail pictures:
Related Product Guide:
Cooperation
Our products are broadly identified and trustworthy by people and may meet continually modifying financial and social requires of High reputation 33kv Substation - S11/S13/S14/S15 Series Full Sealed Oil-Immersed Distribution Power Transformer – Pengbian , The product will supply to all over the world, such as: Netherlands , Eindhoven , Holland , "Make the women more attractive "is our sales philosophy. "Being customers' trusted and preferred brand supplier" is the goal of our company. We are strict with every part of our work. We sincerely welcome friends to negotiate business and start cooperation. We hope to join hands with friends in different industries to create a brilliant future.