Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian
Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian Detail:
Types of meaning

S13-M series 10 kv three-phase double winding excitation regulating distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss  | 
 No-load current (%)  | 
 Short circuit impedance (%) 4.0  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 30  | 
 6 6.3 6.6 10 10.5 11  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yzn11 Yyno  | 
 80  | 
 630/660  | 
 1.2  | 
 4.0  | 
| 
 50  | 
 100  | 
 910/870  | 
 1.0  | 
|||||
| 
 63  | 
 110  | 
 1090/1040  | 
 0.95  | 
|||||
| 
 80  | 
 130  | 
 1310/1250  | 
 0.95  | 
|||||
| 
 100  | 
 150  | 
 1580/1500  | 
 0.90  | 
|||||
| 
 125  | 
 170  | 
 1890/1800  | 
 0.90  | 
|||||
| 
 160  | 
 200  | 
 2310/2200  | 
 0.80  | 
|||||
| 
 200  | 
 240  | 
 2730/2600  | 
 0.80  | 
|||||
| 
 250  | 
 290  | 
 3200/3050  | 
 0.70  | 
|||||
| 
 315  | 
 340  | 
 3830/3650  | 
 0.70  | 
|||||
| 
 400  | 
 410  | 
 4520/4300  | 
 0.65  | 
|||||
| 
 500  | 
 480  | 
 5410/5150  | 
 0.65  | 
|||||
| 
 630  | 
 Dyn11 Yyno  | 
 570  | 
 6200  | 
 0.45  | 
 4.5  | 
|||
| 
 800  | 
 700  | 
 7500  | 
 0.45  | 
|||||
| 
 1000  | 
 830  | 
 10300  | 
 0.45  | 
|||||
| 
 1250  | 
 970  | 
 12000  | 
 0.40  | 
|||||
| 
 1600  | 
 1170  | 
 14500  | 
 0.40  | 
|||||
| 
 2000  | 
 1550  | 
 18300  | 
 0.30  | 
 5.0  | 
||||
| 
 2500  | 
 1830  | 
 21200  | 
 0.30  | 
|||||
e: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
S13-M series of 20 kv three-phase double winding non-field excitation changer distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss (w)  | 
 No-load current (%)  | 
 Short circuit impedance (%)  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 30  | 
 20 22 24  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yzn11 Yyno  | 
 80  | 
 690/660  | 
 2.1  | 
 5.5  | 
| 
 50  | 
 100  | 
 1010/960  | 
 2  | 
|||||
| 
 63  | 
 110  | 
 1200/1150  | 
 1.9  | 
|||||
| 
 80  | 
 130  | 
 1440/1370  | 
 1.8  | 
|||||
| 
 100  | 
 150  | 
 1730/1650  | 
 1.6  | 
|||||
| 
 125  | 
 170  | 
 2080/1980  | 
 1.5  | 
|||||
| 
 160  | 
 200  | 
 2540/2420  | 
 1.4  | 
|||||
| 
 200  | 
 240  | 
 3000/2860  | 
 1.3  | 
|||||
| 
 250  | 
 290  | 
 3520/3350  | 
 1.20  | 
|||||
| 
 315  | 
 340  | 
 4210/4010  | 
 1.10  | 
|||||
| 
 400  | 
 410  | 
 4970/4730  | 
 100  | 
|||||
| 
 500  | 
 480  | 
 5940/5660  | 
 1.00  | 
|||||
| 
 630  | 
 570  | 
 6820  | 
 0.90  | 
 6.0  | 
||||
| 
 800  | 
 700  | 
 8250  | 
 0.80  | 
|||||
| 
 1000  | 
 830  | 
 11330  | 
 0.70  | 
|||||
| 
 1250  | 
 970  | 
 13200  | 
 0.70  | 
|||||
| 
 1600  | 
 1170  | 
 15950  | 
 0.60  | 
|||||
| 
 2000  | 
 1550  | 
 19140  | 
 0.60  | 
|||||
| 
 2500  | 
 1830  | 
 22220  | 
 0.50  | 
|||||
S13-M series of 35 kv three-phase double winding non-field excitation changer distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss (w)  | 
 No-load current (%)  | 
 Short circuit impedance (%)  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 50  | 
 35 38.5  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yyn0  | 
 130  | 
 1200/1140  | 
 1.05  | 
 6.5  | 
| 
 100  | 
 185  | 
 2010/1910  | 
 0.90  | 
|||||
| 
 125  | 
 215  | 
 2370/2260  | 
 0.90  | 
|||||
| 
 160  | 
 225  | 
 2820/2680  | 
 0.80  | 
|||||
| 
 200  | 
 270  | 
 3320/3160  | 
 0.80  | 
|||||
| 
 250  | 
 320  | 
 3950/3760  | 
 0.75  | 
|||||
| 
 315  | 
 380  | 
 4750/4530  | 
 0.75  | 
|||||
| 
 400  | 
 460  | 
 5740/5470  | 
 0.65  | 
|||||
| 
 500  | 
 540  | 
 6910/6580  | 
 0.65  | 
|||||
| 
 630  | 
 660  | 
 7860  | 
 0.50  | 
|||||
| 
 800  | 
 780  | 
 9400  | 
 0.50  | 
|||||
| 
 1000  | 
 920  | 
 11500  | 
 0.50  | 
|||||
| 
 1250  | 
 1120  | 
 13900  | 
 0.45  | 
|||||
| 
 1600  | 
 1350  | 
 16600  | 
 0.45  | 
|||||
| 
 2000  | 
 1590  | 
 19700  | 
 0.40  | 
|||||
| 
 2500  | 
 1890  | 
 23200  | 
 0.40  | 
|||||
Note: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
Product detail pictures:
              Related Product Guide:
Cooperation
Our enterprise since its inception, often regards solution excellent as enterprise life, continually strengthen output technology, enhance product high quality and continually strengthen organization total high-quality administration, in strict accordance using the national standard ISO 9001:2000 for Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian , The product will supply to all over the world, such as: Zimbabwe , Indonesia , Slovenia , With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we're trying our best to be your good partner.
Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
                