Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian
Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian Detail:
Types of meaning

S13-M series 10 kv three-phase double winding excitation regulating distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss  | 
 No-load current (%)  | 
 Short circuit impedance (%) 4.0  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 30  | 
 6 6.3 6.6 10 10.5 11  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yzn11 Yyno  | 
 80  | 
 630/660  | 
 1.2  | 
 4.0  | 
| 
 50  | 
 100  | 
 910/870  | 
 1.0  | 
|||||
| 
 63  | 
 110  | 
 1090/1040  | 
 0.95  | 
|||||
| 
 80  | 
 130  | 
 1310/1250  | 
 0.95  | 
|||||
| 
 100  | 
 150  | 
 1580/1500  | 
 0.90  | 
|||||
| 
 125  | 
 170  | 
 1890/1800  | 
 0.90  | 
|||||
| 
 160  | 
 200  | 
 2310/2200  | 
 0.80  | 
|||||
| 
 200  | 
 240  | 
 2730/2600  | 
 0.80  | 
|||||
| 
 250  | 
 290  | 
 3200/3050  | 
 0.70  | 
|||||
| 
 315  | 
 340  | 
 3830/3650  | 
 0.70  | 
|||||
| 
 400  | 
 410  | 
 4520/4300  | 
 0.65  | 
|||||
| 
 500  | 
 480  | 
 5410/5150  | 
 0.65  | 
|||||
| 
 630  | 
 Dyn11 Yyno  | 
 570  | 
 6200  | 
 0.45  | 
 4.5  | 
|||
| 
 800  | 
 700  | 
 7500  | 
 0.45  | 
|||||
| 
 1000  | 
 830  | 
 10300  | 
 0.45  | 
|||||
| 
 1250  | 
 970  | 
 12000  | 
 0.40  | 
|||||
| 
 1600  | 
 1170  | 
 14500  | 
 0.40  | 
|||||
| 
 2000  | 
 1550  | 
 18300  | 
 0.30  | 
 5.0  | 
||||
| 
 2500  | 
 1830  | 
 21200  | 
 0.30  | 
|||||
e: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
S13-M series of 20 kv three-phase double winding non-field excitation changer distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss (w)  | 
 No-load current (%)  | 
 Short circuit impedance (%)  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 30  | 
 20 22 24  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yzn11 Yyno  | 
 80  | 
 690/660  | 
 2.1  | 
 5.5  | 
| 
 50  | 
 100  | 
 1010/960  | 
 2  | 
|||||
| 
 63  | 
 110  | 
 1200/1150  | 
 1.9  | 
|||||
| 
 80  | 
 130  | 
 1440/1370  | 
 1.8  | 
|||||
| 
 100  | 
 150  | 
 1730/1650  | 
 1.6  | 
|||||
| 
 125  | 
 170  | 
 2080/1980  | 
 1.5  | 
|||||
| 
 160  | 
 200  | 
 2540/2420  | 
 1.4  | 
|||||
| 
 200  | 
 240  | 
 3000/2860  | 
 1.3  | 
|||||
| 
 250  | 
 290  | 
 3520/3350  | 
 1.20  | 
|||||
| 
 315  | 
 340  | 
 4210/4010  | 
 1.10  | 
|||||
| 
 400  | 
 410  | 
 4970/4730  | 
 100  | 
|||||
| 
 500  | 
 480  | 
 5940/5660  | 
 1.00  | 
|||||
| 
 630  | 
 570  | 
 6820  | 
 0.90  | 
 6.0  | 
||||
| 
 800  | 
 700  | 
 8250  | 
 0.80  | 
|||||
| 
 1000  | 
 830  | 
 11330  | 
 0.70  | 
|||||
| 
 1250  | 
 970  | 
 13200  | 
 0.70  | 
|||||
| 
 1600  | 
 1170  | 
 15950  | 
 0.60  | 
|||||
| 
 2000  | 
 1550  | 
 19140  | 
 0.60  | 
|||||
| 
 2500  | 
 1830  | 
 22220  | 
 0.50  | 
|||||
S13-M series of 35 kv three-phase double winding non-field excitation changer distribution transformer
| 
 Rated capacity(kVA)  | 
 Voltage Combinationand Tap range  | 
 
 Vector Group Symbol  | 
 No-load loss (W)  | 
 Load loss (w)  | 
 No-load current (%)  | 
 Short circuit impedance (%)  | 
||
| 
 High pressure  | 
 High pressure tap range (%)  | 
 Low ressure (kV)  | 
||||||
| 
 50  | 
 35 38.5  | 
 ±2×2.5 ±5  | 
 0.4  | 
 Dyn11 Yyn0  | 
 130  | 
 1200/1140  | 
 1.05  | 
 6.5  | 
| 
 100  | 
 185  | 
 2010/1910  | 
 0.90  | 
|||||
| 
 125  | 
 215  | 
 2370/2260  | 
 0.90  | 
|||||
| 
 160  | 
 225  | 
 2820/2680  | 
 0.80  | 
|||||
| 
 200  | 
 270  | 
 3320/3160  | 
 0.80  | 
|||||
| 
 250  | 
 320  | 
 3950/3760  | 
 0.75  | 
|||||
| 
 315  | 
 380  | 
 4750/4530  | 
 0.75  | 
|||||
| 
 400  | 
 460  | 
 5740/5470  | 
 0.65  | 
|||||
| 
 500  | 
 540  | 
 6910/6580  | 
 0.65  | 
|||||
| 
 630  | 
 660  | 
 7860  | 
 0.50  | 
|||||
| 
 800  | 
 780  | 
 9400  | 
 0.50  | 
|||||
| 
 1000  | 
 920  | 
 11500  | 
 0.50  | 
|||||
| 
 1250  | 
 1120  | 
 13900  | 
 0.45  | 
|||||
| 
 1600  | 
 1350  | 
 16600  | 
 0.45  | 
|||||
| 
 2000  | 
 1590  | 
 19700  | 
 0.40  | 
|||||
| 
 2500  | 
 1890  | 
 23200  | 
 0.40  | 
|||||
Note: for the rated capacity of 500 kva and below transformer, load loss value of the diagonal lines in the table above apply to Dyn11 or Yzn11 link group, slash at the bottom of the load loss value applies to Yyno link group.
Product detail pictures:
              Related Product Guide:
Cooperation
Assume full accountability to satisfy all demands of our consumers; reach ongoing advancements by endorsing the expansion of our purchasers; come to be the final permanent cooperative partner of clients and maximize the interests of clientele for Good Quality S11 Series Of Oil-Immersed Transformer - S13 Series Of Oil-Immersed Transformer – Pengbian , The product will supply to all over the world, such as: Mumbai , Nepal , New Delhi , Further, we are supported by highly experienced and knowledgeable professionals, who have immense expertise in their respective domain. These professionals work in close coordination with each other to offer our clients an effective range of products.
A good manufacturers, we have cooperated twice, good quality and good service attitude.
                