Earthing Transformer - GGJ Low Voltage Reactive Compensation Equipment 0.4kV Switchgear Type Metal Electrical Control Load Center – Pengbian

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for Dyn11 Or Yyn0 Power Transformer , 120v Transformer , American Box Substation , We always regard the technology and prospects as the uppermost. We always function hard to make terrific values for our prospects and give our customers far better products and solutions & solutions.
Earthing Transformer - GGJ Low Voltage Reactive Compensation Equipment 0.4kV Switchgear Type Metal Electrical Control Load Center – Pengbian Detail:

Overview

As this device can effectively improve the power factor of the electrical load, reduce the line loss, and improve the actual load capacity of the transformer, it has a significant energy saving effect. At the same time, the use of a specific reactor in the system can also be effective Prevent harmonic amplification and effectively absorb most of the harmonic currents, so that the harmonic voltage total distortion rate limit and the harmonic current content limit of each sub-harmonic current meet the national standards, and achieve the purpose of harmonic control. And if you use an ordinary contactor to cast Cutting the capacitor bank will bring about large inrush current, slow compensation time, high maintenance cost and short service life. Therefore, we recommend that users give priority to dynamic reactive power compensation in the following situations Devices such as: low-voltage power grids in industrial and mining enterprises’ substations, production workshops, and civil buildings are particularly suitable for transmission and distribution systems with frequent changes in load and unstable reactive power.

This product complies with: G8/T15576-2008 “Low-voltage complete set of reactive power compensation equipment”, IEC60439 “Low-voltage complete set of switchgear and control equipment” and other standards.

Model meaning

MODEL: GGJ □ □ □

GGJ: Compensation cabinet
□: Compensation method: 1 is dynamic compensation, normal can be omitted
□: Compensation capacity: kVar
□: Voltage level: 230V400V
□: Wiring mode: D-angle wiring, Y-star wiring

Conditions of Use

•  Ambient temperature: -5°C-+40r;
• Environmental relative humidity: no more than 90% (20℃);
• Altitude: not more than 2000m;
• There is no danger of explosion in the surrounding medium, no gas that can damage and corrode metals, no conductive dust, no severe vibration at the installation site, and no rain or snow erosion.

Features

◆ Automatically compensate reactive power and improve power factor.
◆ Improve equipment efficiency and save investment.
◆ Reduce power distribution line loss and transformer loss.
◆ Change the voltage quality and improve the reliability of power supply.
◆ Strong general performance: The compensation cabinet can be combined with any cabinets at home and abroad, such as MNS, GCK, GGD, etc.;
◆ Capacitor compensation combination methods are diverse and flexible: Y-type compensation method, A-type compensation method, Y+A combined compensation method are available;
◆ Diversified communication methods: with RS-232/485 communication interface, wireless data transmission module or GPRS module for long-distance communication;
◆ Control is accurate and safe: the voltage zero-crossing trigger is implemented, there is no surge current zero-crossing removal when switching on, and no high voltage is generated when breaking;
◆ Long service life: Under maintenance-free, the service life can reach more than 100,000 hours.

Specification
Item
Data
System Rated Voltage (V)
≤450
Switch Time (ms)
≤20
Rated Frequency (Hz)
50(60)
Input Surge (In)
<25
Sample Current(A)
0~5
Power Consumption (W)
≤15
Sensitivity (mA)
100

Product detail pictures:

Earthing Transformer -
 GGJ Low Voltage Reactive Compensation Equipment 0.4kV Switchgear Type Metal Electrical Control Load Center – Pengbian detail pictures

Earthing Transformer -
 GGJ Low Voltage Reactive Compensation Equipment 0.4kV Switchgear Type Metal Electrical Control Load Center – Pengbian detail pictures


Related Product Guide:
Cooperation

We believe in: Innovation is our soul and spirit. Quality is our life. Shopper need is our God for Earthing Transformer - GGJ Low Voltage Reactive Compensation Equipment 0.4kV Switchgear Type Metal Electrical Control Load Center – Pengbian , The product will supply to all over the world, such as: Washington , Stuttgart , Namibia , As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products we offer, effective and satisfying consultation service is supplied by our specialist after-sale service group. Solution lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we are going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.
  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Linda from venezuela - 2017.04.08 14:55
    Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Joseph from Panama - 2018.06.03 10:17
    Write your message here and send it to us
    WhatsApp Online Chat !